1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
|
--
-- First we build the house - so we create the rooms
--
insert into Room values ('001', 'Entrance');
insert into Room values ('002', 'Office');
insert into Room values ('003', 'Office');
insert into Room values ('004', 'Technical');
insert into Room values ('101', 'Office');
insert into Room values ('102', 'Conference');
insert into Room values ('103', 'Restroom');
insert into Room values ('104', 'Technical');
insert into Room values ('105', 'Office');
insert into Room values ('106', 'Office');
--
-- Second we install the wall connectors
--
insert into WSlot values ('WS.001.1a', '001', '', '');
insert into WSlot values ('WS.001.1b', '001', '', '');
insert into WSlot values ('WS.001.2a', '001', '', '');
insert into WSlot values ('WS.001.2b', '001', '', '');
insert into WSlot values ('WS.001.3a', '001', '', '');
insert into WSlot values ('WS.001.3b', '001', '', '');
insert into WSlot values ('WS.002.1a', '002', '', '');
insert into WSlot values ('WS.002.1b', '002', '', '');
insert into WSlot values ('WS.002.2a', '002', '', '');
insert into WSlot values ('WS.002.2b', '002', '', '');
insert into WSlot values ('WS.002.3a', '002', '', '');
insert into WSlot values ('WS.002.3b', '002', '', '');
insert into WSlot values ('WS.003.1a', '003', '', '');
insert into WSlot values ('WS.003.1b', '003', '', '');
insert into WSlot values ('WS.003.2a', '003', '', '');
insert into WSlot values ('WS.003.2b', '003', '', '');
insert into WSlot values ('WS.003.3a', '003', '', '');
insert into WSlot values ('WS.003.3b', '003', '', '');
insert into WSlot values ('WS.101.1a', '101', '', '');
insert into WSlot values ('WS.101.1b', '101', '', '');
insert into WSlot values ('WS.101.2a', '101', '', '');
insert into WSlot values ('WS.101.2b', '101', '', '');
insert into WSlot values ('WS.101.3a', '101', '', '');
insert into WSlot values ('WS.101.3b', '101', '', '');
insert into WSlot values ('WS.102.1a', '102', '', '');
insert into WSlot values ('WS.102.1b', '102', '', '');
insert into WSlot values ('WS.102.2a', '102', '', '');
insert into WSlot values ('WS.102.2b', '102', '', '');
insert into WSlot values ('WS.102.3a', '102', '', '');
insert into WSlot values ('WS.102.3b', '102', '', '');
insert into WSlot values ('WS.105.1a', '105', '', '');
insert into WSlot values ('WS.105.1b', '105', '', '');
insert into WSlot values ('WS.105.2a', '105', '', '');
insert into WSlot values ('WS.105.2b', '105', '', '');
insert into WSlot values ('WS.105.3a', '105', '', '');
insert into WSlot values ('WS.105.3b', '105', '', '');
insert into WSlot values ('WS.106.1a', '106', '', '');
insert into WSlot values ('WS.106.1b', '106', '', '');
insert into WSlot values ('WS.106.2a', '106', '', '');
insert into WSlot values ('WS.106.2b', '106', '', '');
insert into WSlot values ('WS.106.3a', '106', '', '');
insert into WSlot values ('WS.106.3b', '106', '', '');
--
-- Now create the patch fields and their slots
--
insert into PField values ('PF0_1', 'Wallslots basement');
--
-- The cables for these will be made later, so they are unconnected for now
--
insert into PSlot values ('PS.base.a1', 'PF0_1', '', '');
insert into PSlot values ('PS.base.a2', 'PF0_1', '', '');
insert into PSlot values ('PS.base.a3', 'PF0_1', '', '');
insert into PSlot values ('PS.base.a4', 'PF0_1', '', '');
insert into PSlot values ('PS.base.a5', 'PF0_1', '', '');
insert into PSlot values ('PS.base.a6', 'PF0_1', '', '');
--
-- These are already wired to the wall connectors
--
insert into PSlot values ('PS.base.b1', 'PF0_1', '', 'WS.002.1a');
insert into PSlot values ('PS.base.b2', 'PF0_1', '', 'WS.002.1b');
insert into PSlot values ('PS.base.b3', 'PF0_1', '', 'WS.002.2a');
insert into PSlot values ('PS.base.b4', 'PF0_1', '', 'WS.002.2b');
insert into PSlot values ('PS.base.b5', 'PF0_1', '', 'WS.002.3a');
insert into PSlot values ('PS.base.b6', 'PF0_1', '', 'WS.002.3b');
insert into PSlot values ('PS.base.c1', 'PF0_1', '', 'WS.003.1a');
insert into PSlot values ('PS.base.c2', 'PF0_1', '', 'WS.003.1b');
insert into PSlot values ('PS.base.c3', 'PF0_1', '', 'WS.003.2a');
insert into PSlot values ('PS.base.c4', 'PF0_1', '', 'WS.003.2b');
insert into PSlot values ('PS.base.c5', 'PF0_1', '', 'WS.003.3a');
insert into PSlot values ('PS.base.c6', 'PF0_1', '', 'WS.003.3b');
--
-- This patchfield will be renamed later into PF0_2 - so its
-- slots references in pfname should follow
--
insert into PField values ('PF0_X', 'Phonelines basement');
insert into PSlot values ('PS.base.ta1', 'PF0_X', '', '');
insert into PSlot values ('PS.base.ta2', 'PF0_X', '', '');
insert into PSlot values ('PS.base.ta3', 'PF0_X', '', '');
insert into PSlot values ('PS.base.ta4', 'PF0_X', '', '');
insert into PSlot values ('PS.base.ta5', 'PF0_X', '', '');
insert into PSlot values ('PS.base.ta6', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb1', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb2', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb3', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb4', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb5', 'PF0_X', '', '');
insert into PSlot values ('PS.base.tb6', 'PF0_X', '', '');
insert into PField values ('PF1_1', 'Wallslots 1st floor');
insert into PSlot values ('PS.1st.a1', 'PF1_1', '', 'WS.101.1a');
insert into PSlot values ('PS.1st.a2', 'PF1_1', '', 'WS.101.1b');
insert into PSlot values ('PS.1st.a3', 'PF1_1', '', 'WS.101.2a');
insert into PSlot values ('PS.1st.a4', 'PF1_1', '', 'WS.101.2b');
insert into PSlot values ('PS.1st.a5', 'PF1_1', '', 'WS.101.3a');
insert into PSlot values ('PS.1st.a6', 'PF1_1', '', 'WS.101.3b');
insert into PSlot values ('PS.1st.b1', 'PF1_1', '', 'WS.102.1a');
insert into PSlot values ('PS.1st.b2', 'PF1_1', '', 'WS.102.1b');
insert into PSlot values ('PS.1st.b3', 'PF1_1', '', 'WS.102.2a');
insert into PSlot values ('PS.1st.b4', 'PF1_1', '', 'WS.102.2b');
insert into PSlot values ('PS.1st.b5', 'PF1_1', '', 'WS.102.3a');
insert into PSlot values ('PS.1st.b6', 'PF1_1', '', 'WS.102.3b');
insert into PSlot values ('PS.1st.c1', 'PF1_1', '', 'WS.105.1a');
insert into PSlot values ('PS.1st.c2', 'PF1_1', '', 'WS.105.1b');
insert into PSlot values ('PS.1st.c3', 'PF1_1', '', 'WS.105.2a');
insert into PSlot values ('PS.1st.c4', 'PF1_1', '', 'WS.105.2b');
insert into PSlot values ('PS.1st.c5', 'PF1_1', '', 'WS.105.3a');
insert into PSlot values ('PS.1st.c6', 'PF1_1', '', 'WS.105.3b');
insert into PSlot values ('PS.1st.d1', 'PF1_1', '', 'WS.106.1a');
insert into PSlot values ('PS.1st.d2', 'PF1_1', '', 'WS.106.1b');
insert into PSlot values ('PS.1st.d3', 'PF1_1', '', 'WS.106.2a');
insert into PSlot values ('PS.1st.d4', 'PF1_1', '', 'WS.106.2b');
insert into PSlot values ('PS.1st.d5', 'PF1_1', '', 'WS.106.3a');
insert into PSlot values ('PS.1st.d6', 'PF1_1', '', 'WS.106.3b');
--
-- Now we wire the wall connectors 1a-2a in room 001 to the
-- patchfield. In the second update we make an error, and
-- correct it after
--
update PSlot set backlink = 'WS.001.1a' where slotname = 'PS.base.a1';
update PSlot set backlink = 'WS.001.1b' where slotname = 'PS.base.a3';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
update PSlot set backlink = 'WS.001.2a' where slotname = 'PS.base.a3';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
update PSlot set backlink = 'WS.001.1b' where slotname = 'PS.base.a2';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
--
-- Same procedure for 2b-3b but this time updating the WSlot instead
-- of the PSlot. Due to the triggers the result is the same:
-- WSlot and corresponding PSlot point to each other.
--
update WSlot set backlink = 'PS.base.a4' where slotname = 'WS.001.2b';
update WSlot set backlink = 'PS.base.a6' where slotname = 'WS.001.3a';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
update WSlot set backlink = 'PS.base.a6' where slotname = 'WS.001.3b';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
update WSlot set backlink = 'PS.base.a5' where slotname = 'WS.001.3a';
select * from WSlot where roomno = '001' order by slotname;
select * from PSlot where slotname ~ 'PS.base.a' order by slotname;
insert into PField values ('PF1_2', 'Phonelines 1st floor');
insert into PSlot values ('PS.1st.ta1', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.ta2', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.ta3', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.ta4', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.ta5', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.ta6', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb1', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb2', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb3', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb4', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb5', 'PF1_2', '', '');
insert into PSlot values ('PS.1st.tb6', 'PF1_2', '', '');
--
-- Fix the wrong name for patchfield PF0_2
--
update PField set name = 'PF0_2' where name = 'PF0_X';
select * from PSlot order by slotname;
select * from WSlot order by slotname;
--
-- Install the central phone system and create the phone numbers.
-- They are weired on insert to the patchfields. Again the
-- triggers automatically tell the PSlots to update their
-- backlink field.
--
insert into PLine values ('PL.001', '-0', 'Central call', 'PS.base.ta1');
insert into PLine values ('PL.002', '-101', '', 'PS.base.ta2');
insert into PLine values ('PL.003', '-102', '', 'PS.base.ta3');
insert into PLine values ('PL.004', '-103', '', 'PS.base.ta5');
insert into PLine values ('PL.005', '-104', '', 'PS.base.ta6');
insert into PLine values ('PL.006', '-106', '', 'PS.base.tb2');
insert into PLine values ('PL.007', '-108', '', 'PS.base.tb3');
insert into PLine values ('PL.008', '-109', '', 'PS.base.tb4');
insert into PLine values ('PL.009', '-121', '', 'PS.base.tb5');
insert into PLine values ('PL.010', '-122', '', 'PS.base.tb6');
insert into PLine values ('PL.015', '-134', '', 'PS.1st.ta1');
insert into PLine values ('PL.016', '-137', '', 'PS.1st.ta3');
insert into PLine values ('PL.017', '-139', '', 'PS.1st.ta4');
insert into PLine values ('PL.018', '-362', '', 'PS.1st.tb1');
insert into PLine values ('PL.019', '-363', '', 'PS.1st.tb2');
insert into PLine values ('PL.020', '-364', '', 'PS.1st.tb3');
insert into PLine values ('PL.021', '-365', '', 'PS.1st.tb5');
insert into PLine values ('PL.022', '-367', '', 'PS.1st.tb6');
insert into PLine values ('PL.028', '-501', 'Fax entrance', 'PS.base.ta2');
insert into PLine values ('PL.029', '-502', 'Fax 1st floor', 'PS.1st.ta1');
--
-- Buy some phones, plug them into the wall and patch the
-- phone lines to the corresponding patchfield slots.
--
insert into PHone values ('PH.hc001', 'Hicom standard', 'WS.001.1a');
update PSlot set slotlink = 'PS.base.ta1' where slotname = 'PS.base.a1';
insert into PHone values ('PH.hc002', 'Hicom standard', 'WS.002.1a');
update PSlot set slotlink = 'PS.base.ta5' where slotname = 'PS.base.b1';
insert into PHone values ('PH.hc003', 'Hicom standard', 'WS.002.2a');
update PSlot set slotlink = 'PS.base.tb2' where slotname = 'PS.base.b3';
insert into PHone values ('PH.fax001', 'Canon fax', 'WS.001.2a');
update PSlot set slotlink = 'PS.base.ta2' where slotname = 'PS.base.a3';
--
-- Install a hub at one of the patchfields, plug a computers
-- ethernet interface into the wall and patch it to the hub.
--
insert into Hub values ('base.hub1', 'Patchfield PF0_1 hub', 16);
insert into System values ('orion', 'PC');
insert into IFace values ('IF', 'orion', 'eth0', 'WS.002.1b');
update PSlot set slotlink = 'HS.base.hub1.1' where slotname = 'PS.base.b2';
--
-- Now we take a look at the patchfield
--
select * from PField_v1 where pfname = 'PF0_1' order by slotname;
select * from PField_v1 where pfname = 'PF0_2' order by slotname;
--
-- Finally we want errors
--
insert into PField values ('PF1_1', 'should fail due to unique index');
update PSlot set backlink = 'WS.not.there' where slotname = 'PS.base.a1';
update PSlot set backlink = 'XX.illegal' where slotname = 'PS.base.a1';
update PSlot set slotlink = 'PS.not.there' where slotname = 'PS.base.a1';
update PSlot set slotlink = 'XX.illegal' where slotname = 'PS.base.a1';
insert into HSlot values ('HS', 'base.hub1', 1, '');
insert into HSlot values ('HS', 'base.hub1', 20, '');
delete from HSlot;
insert into IFace values ('IF', 'notthere', 'eth0', '');
insert into IFace values ('IF', 'orion', 'ethernet_interface_name_too_long', '');
|